Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13758445
- Product Categories
- Friendly Links
- home > Supply > GWS automatic pipeline booster pump, automatic municipal water booster equipment, automatic booster pumps
GWS automatic pipeline booster pump, automatic municipal water booster equipment, automatic booster pumps
Information Name: | GWS automatic pipeline booster pump, automatic municipal water booster equipment, automatic booster pumps |
Published: | 2015-05-06 |
Validity: | 999 |
Specifications: | Cover |
Quantity: | 20.00 |
Price Description: | |
Detailed Product Description: | GWS frequency automatic pipeline booster pump water _ Guangzhou automatic pressure pump manufacturers offer automatic pressurized municipal water equipment, automatic booster pumps, automatic water booster pumps, high-rise building pressurized water supply equipment. Construction site temporary water booster pumps. Overall Summary GWS series automatic booster (differential pressure type & variable frequency & level) is a user changes in water according to automatically pressurized secondary water supply system, also known as the water industry automatic pressurization pump reliability is one of the devices on the market and use of the best. A wide range of equipment performance, simple operation, control and protection functions, economical and practical. It is the site of temporary water supply, small office buildings and commercial buildings and other occasions (toilet hand washing or flushing water) Ideal water pressurized equipment. (Non-inverter) automatic pipeline booster pump system classification / principle of differential pressure level schematic automatic pipeline booster pump, the device shown in addition to the accessories, you need to configure the level float switch. Inverter automatic pipeline booster pump (ie variable-speed pump) system diagram booster structure according to different points: Vertical single-stage pipeline automatic booster: Booster GD cast iron pipe vertical single-stage centrifugal pumps, line part defaults steel pipe. Cast iron vertical multistage centrifugal automatic booster: Booster cast iron VP vertical multistage centrifugal or cast iron DL vertical multistage centrifugal pump, pipeline steel pipe section defaults. Vertical multistage stainless steel automatic booster: Booster CRF with stainless steel vertical multistage stainless steel pipeline pump, valve portion may be stainless steel or steel pipe according to actual needs. Note: The above three models Whichever you choose, controllers are using the same paragraph. Divided according to the principle: differential pressure: differential pressure by a common electrical control cabinet, booster pumps, electrical contacts (water protection and pressure settings), pressure tank, check valves, valve, base and other components; use direct tandem on direct pressurized water pipes. Through the electrical contacts pre-set operating range (upper and lower pressure limits), the boot operation, the device starts running pressurized pipeline pressure when the pressure rises to the upper limit of the user preset value, the electric contact pressure gauge the role, immediately shut down the pump to maintain pressure; when the open faucet water pipe network pressure drop, once the low pressure at the pressure limits set by the user, the pump restarts boosting. Reciprocating cycle will reach constant pressure water supply. In special cases, you can use two pumps in turn initiates a switchover. Level type: level style (no frequency) by a common electrical control cabinet, booster pumps, liquid level float switch (level control), electric contact pressure gauge (water protection), check valves, valve, base, etc. composition; when used in series with the water pipe, water pipe through the second pressurized water will be transported to the roof pool / water tower, when the pond / water level in the water reaches the pre-set high level in the float the role of the switch pump stops running, when the user of water caused the water level drops to the lower limit level set in advance, in the role of the pump float switch restarts pressurized water supply. Cyclical continuous water supply purposes. In special cases, you can use two pumps in turn initiates a switchover. Inverter: Inverter by the frequency control cabinet, booster pumps, electrical contacts (from water protection), remote pressure gauge (pressure data feedback), pressure tank, check valves, valve, base and other components. By pre-set constant pressure, remote pressure gauge constantly at work gathering pipeline pressure data and feedback to the controller, real-time adjust the pump speed by comparing the user preset value and the actual pressure value to correct the pressure deviation value, and so they constant pressure water supply purposes. Under special circumstances, inverter-type horizontal booster pump can be used to make an automatic frequency control booster II. Performance range Model Flow m3 / h Head range m Equipment Power kw pump units Caliber mm GWS2-14-182 2 14-182 0.37-3 1 25 GWS 4-12-160 4 12-143 0.37-4 1 25 GWS 6- 9-162 6 6-144 0.37-5.5 1 25 GWS 8-8.5-196 8 8.5-196 0.37-7.5 1 40 GWS 10-8-176 10 8-176 0.37-7.5 1 40 GWS 12-6-146 12 12 -146 0.37-7.5 1 40 GWS 14-11-195 14 11-195 1.1-15 1 50 GWS 16-8-150 16 8-150 0.75-15 1 50 GWS 20-11-187 20 11-187 1.1-18.5 1 65 GWS 24-12-218 24 12-218 1.5-30 1 65 GWS 32-10-150 32 10-174 1.5-30 1 65 GWS 36-9-144 36 9-144 1.5-30 1 80 GWS 45- 15-1664515-166 3.0-30 180 features a wide range of performance. You can select a variety of venues match the best performance or the pump according to the actual situation as a booster when the device power ≤2.2KW, can take 220V / 380V power supply modes, so that the device can meet also meet the general civil engineering Agricultural production needs. 2, the pressure and water level stabilized. System configuration of small pressure tank / level switches to ensure stable water peak pipeline pressures and pool water level. 3, the economic benefits. Single pump pressurization, either node control or frequency control, control parts are without PLC or microcontroller programming control, and numerous complex piping, effective control of product costs and can ensure a stable water supply. 4, high reliability. The overall use of electrical components to control the device, whether it is life and ease of use are higher than the use of electronic regulator devices currently on the market, and when the control device fails, only need to replace the General Electric components to quickly ruled out, rather than professionals can not replace or repair the integrated electronic ballast control equipment. In addition, the device control components are used well-known brands, effectively reducing the system failure. Pressure pump can choose different brands based on customer requirements, the use of our products, no special requirements. 5, the protection function. Needed to achieve leakage, overload, overcurrent, short circuit, over-pressure and water and other conventional protection. 6, easy installation and operation. With a control device itself is a function of pipeline pumps, pump inlet and outlet piping same size and located along the same line, extremely easy to install, after power to the device can be fully automatic operation, no manned. Applications Domestic water supply: small residential areas, small office buildings and villages building group and other occasions pressurized water. Industrial water: plant a variety of production flow water delivery. Building site: high-rise building construction site construction temporary water, mud tank pressurization system wheel wash, rinse the floor pressurization device. Sprinkler Irrigation: farms, orchards, gardens and other occasions sprinkler irrigation. Other booster: industry equipment washing and cleaning apparatus pressurization, equipment pressurized. Installation Notes In order not to affect the life of the product and reduce its performance, the installation site must be selected, taking care to mounting direction or the surrounding space. Accessories such as equipment is sent to the demand-side approach does not require the company responsible for the installation, schematic assembly unit in strict accordance with our offer. Pump and associated piping installation 1, the equipment should be installed indoors or in sheltered outdoor locations, the ambient temperature is between 5 ℃ ~ 40 ℃, relative humidity less than 90%, and should have good ventilation, can not exist around flammable explosive or corrosive gas or liquid, the venue is not higher than 2000 meters above sea level. 2, matching pumps water pump water pumps should be installed in accordance with manufacturer's installation instructions, peripheral piping and equipment into the water pipe connections (water pipe or pond water pipes) must be in strict accordance with the attached equipment into the water pipe sizes arrangements should do peripheral pipe diameter ≥ equipment into the water pipe inside diameter. 3, equipment layout and installation diagram or the relevant national norms, there must be in strict accordance with the construction drawings design drawings. 4, pump suction way should be self-leveling, non-self-fill water must have a reliable guarantee. 5. If the device is mounted on the board, recommended damping device, otherwise it will bring noise or vibration. Install this series frequency control cabinet control system according to different power have the appropriate weight must be used when handling the appropriate handling methods, so as not to fall or collision damage caused by some components. Should also note the following: 1, the surrounding environment control system is large, the installation must avoid direct sunlight, high temperature, humidity of the place, the environment temperature should be -10 ℃ ~ 40 ℃, relative humidity less than 90% , not susceptible of condensation / frost and so on. 2, the installation site should avoid oil mist, flammable gas liquids, cotton dust, etc. 3. Tighten control cabinet. The use of floor-standing control cabinet, screws must be used vertically and firmly fixed on the base of pre-configured, while ensuring distance control cabinet base and the ground is not less than 10 cm; such as the use wall-mounted, must ensure that sufficient efforts suspension and the wall must not be too wet. 4, wiring, banned all off-cuts, screws and other metal objects fall into the control cabinet. Otherwise easily lead to obstacles control system malfunction to set serious consequences of damage. 5, due to the frequency control system is equipped with a frequency converter, therefore, contain high-frequency components of the control system of the input and output circuits, the use of communication devices in the vicinity of the control cabinet may bring against electromagnetic interference, then you can install preaching radio noise filter or noise filter to reduce interference. Wiring Method and Precautions wiring diagram (mainly electrical contacts, remote pressure gauge, float, power supply wiring, pump motor wiring) Refer to the attached device control schematic. When wiring, pay special attention to the following precautions. If not understand, please contact me in order to avoid or can not properly use the equipment and personal safety caused by accidents. 1. Wiring precautions 1.1 power access, and wiring of all motors must be connected to the standard configuration and wiring method requires absolutely right, if there is an error would be likely to cause significant damage to the equipment. The following is the power and wire size table, please strict selection of quality standard wires, or may cause damage to property according to power equipment. 1.2 All power input, and connected to the motor line scripts please use sleeved solderless terminals. 1.3 cable is connected to the control circuit terminals, use shielded or twisted wire. And with the main circuit wiring and power circuits separate, later operation, if the need to change the wiring, wait 10 minutes after a power failure was observed after the operation can be carried out inside the inverter frequency control charge indicator goes off. Otherwise it will cause an electric shock! 1.4 is connected to the motor cable must be in strict accordance with the standard configuration. 1.5 is connected to the control circuit wiring scripts use 1.5mm2 single strand wire from less than 1,000 meters, where the wires connected to the pressure sensor to use at least 0.75mm2 shielded cable connection distance of not more than 300 meters. 2. Grounding Considerations 2.1 In order to prevent electric shock, we must ensure that this series of frequency control cabinet and motor grounded, grounding resistance 10Ω or less guaranteed. 2.2 Ground control cabinet, connect a dedicated ground terminal, do not use screws and other cabinet members, and the yellow and green lines with a professional identity. 2.3 motor grounding terminal using a 4-core cable in a line, the ground under control. 2.4 main circuit wiring, configure according to relevant regulations depending on the motor starts. Operating environment Ambient temperature should be between 5-50 ℃, relative humidity less than 90%, no condensation. Ambient air non-corrosive gases, explosive gas, vapor, dust and other pollution. Installation site is not higher than the maximum altitude of 1500 meters, high altitude use should be particularly pointed. Installation gradient does not exceed 5 °. Handling Precautions 1, the device is a strong electrical device should hold a certificate of electrician. 2, the device must be configured in accordance with the maximum power of sufficient capacity wires, and check the power supply voltage, phase, frequency is consistent with the equipment nameplate, the ground is reliable, and connect the cable wiring in accordance with the provisions of law devices. 3, when the initial start using jog mode to ensure proper motor rotation. Single-phase power supply equipment without paying attention to this. 4, the pump transmission medium temperature and corrosive acid salt shall not exceed the scope of this pump is made of. 5, the pump is installed, you must ensure that access to the pipe diameter (including valve diameter) is equal to the pump input diameter, or may appear insufficient water cause the device to not work properly. 6, if the pump inlet pipe mouth fitted with filters, mesh filters must ensure that the total area of ??not less than the pump inlet area, and regular cleaning of the filter, blocked intake or impurity caused by lack of water pump device stops working. 7, during operation, the pump must ensure that the input pipe does not leak, or cause insufficient pressure or no water suction failure. 8, the pump is not appropriate outside its marked head and flow range, otherwise damage to the motor or increased noise. 9, the pump is handling or installation, should be handled with care. 10, the device maximum mounting height (distance from water pump inlet in meters) of the formula: 10.33- must cavitation margin value -1.5 m safety value, the actual installation height values ??as small as possible is appropriate, the maximum shall more than the calculated value, otherwise the pump will cause cavitation suction efficiency is too low or no water, more severe cases can damage the pump parts. 11. Do not attempt to adjust the water protection switch, or the device may be due to loss of water protection damage the pump. Gauge wiring and calibration methods, such as using a multimeter are measuring gauge between two of the three lines, the 3rd largest of any resistance value of the terminals connected to the controller and 5 terminals, terminal 1 connected to the remaining one controller , connected into the system parameters, based on the actual range selection pressure gauge pressure gauge on the controller's range. Take a good line, you must check the gauge wiring methods are correct. Specific detection method as follows: manually open the pump, observe the pressure gauge trends are consistent with the actual pressure value is displayed on the controller, if consensus proves correct wiring; if the value of the gauge is on the rise, and the control panel display Pressure display is on the decline, then prove access terminal 3 and the ground terminal of the 5th line reversed, exchange the two cable. After the wiring is correct, enter the pressure calibration procedure. Specific operational procedures: first manually open Renyiyitai pump, then the gauge readings actually enter into the press to confirm, pay attention to the same value can not be calibrated twice. It represents misuse operation twice, for example: pressure gauge reading after 0.23Mpa enter 0.23 to confirm press ENT. The next time you can not enter calibration is 0.23, you must enter another value recalibration. It is worth noting that, when the pressure gauge at zero pressure state calibration, do not zero, calibrated to a 0.01, or manually play up the pressure after the correction. Troubleshooting Solution 1, when you open the tap, why not start the pump? Whether or pressure-frequency automatic pressurization equipment, provided the work is below the set pressure value will start the pump, if the a little time around the water pipe network, and devices connected to the pipe network pressure enough, then if someone with water, the water pressure is higher than the pressure we set, in which case the pump will not start. 2. Why booster frequent starts and stops? Frequent starts and stops this phenomenon is generally pressure-automatic pressurization device that appears. The main reason for this phenomenon may be the upper and lower pressure setting too close, when the water peak, the device due to pressure changes in the pipe network client start and stop frequently. Solutions to lower due to lower pressure limit. 3, the pressure is below the set value, why not start or pump? This phenomenon may be caused by water protection, especially when electrical contacts as water protection, water pressure when the set value is too high , if the water pressure is so low that is lower than the set pressure value, then regardless of the user enough pressure, pump will not start to play a role in water protection. 4, pool water level is full or the water level in the end, why not stop or start the pump? This may be because the float level switch is wired incorrectly, reference schematics rewire control. 5, no matter how the device is running, the pressure is why the table show zero? Probably because the meter valve was mistakenly turned off or damaged, replace the check valve is closed or the pressure gauge. Q: I am in the end the selection of differential pressure or frequency type A: You can choose the following scenarios pressure control:? Booster pump flow and head are small (as pumps power 4KW or less); water less frequently ( If water is used for fire station is small or temporary water supply). You must select the following scenarios frequency control: the larger booster pump power (4Kw above); and higher lift (above 50 meters); the number of water more frequently (such as multiple stations often water, etc.). Q: GWS series voltage which A:? GWS series are civil and industrial use. You can configure the 220V / 380V needed. Q: What can one with a prepared? A: Yes, differential pressure, level and type can configure a spare pump, can turn up and running at startup; Inverter configure a spare pump is constant pressure water supply BWS equipment. |
Admin>>>
You are the 6976 visitor
Copyright © GuangDong ICP No. 10089450, Water Technology Co., Ltd. in Guangzhou City Hengsheng All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 6976 visitor
Copyright © GuangDong ICP No. 10089450, Water Technology Co., Ltd. in Guangzhou City Hengsheng All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility